Mfr
Analog Devices Inc./Maxim Integrated
Sensor Type
Digital, Local/Remote
Sensing Temperature - Local
-40°C ~ 125°C
Sensing Temperature - Remote
-64°C ~ 150°C
Voltage - Supply
3V ~ 3.6V
Resolution
8 b (Local), 11 b (Remote)
Features
Output Switch, Programmable Limit, Standby Mode
Accuracy - Highest (Lowest)
±1.5°C (±3.5°C)
Test Condition
30°C ~ 85°C (0°C ~ 150°C)
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
24-WFQFN Exposed Pad
Supplier Device Package
24-TQFN (4x4)
Base Product Number
MAX6581