Added additional EEPROM value for MLX8134X [O_VSMF_CSA_OCD]
Post time:2024-06-05 16:27:41
Poster:Innovo Technology
From:Network
●Description of change
●Change #1
■Old:The offset calibration value for VSMF is valid when internal blocks [CSA and OCD] are switched OFF, this means when NO external motor currentshunt is needed.
■New:The additional offset calibration value for VSMF must be used when the internal blocks [CSA and OCD] are switched ON, this means when an external motor current shunt is used.
●Reason / motivation
■Motivation:The additional calibration is needed to reach in all cases the specified accuracy according to the datasheet.
●Description
■No change in the marking of the parts.
■Traceability ensured by lot number and datecode through the Melexis ERP system.